Oscillation

Below you find short descriptions of EMC PARTNER’s products for

  • damped oscillation

as well as for

  • damped oscillatory and magnetic field tests in one box.

The ring wave test is also included in the One Box EMC Test Station.

MIG-OS-OS1

Waveform (Range): 1 MHz (up to 3 kV), 100 kHz (up to 3 kV),ta = 75 ns
Impedance: 200 Ohm
Standards: IEC 60255-5, IEC 61000-4-18
Option: MF IEC 61000-4-10
Required Accessory: CDN2000-06-25

MIG-OS-OM-EXT

This addition to the damped oscillatory test system adds the 3MHz, 10MHz and 30MHz fast waves to existing generators of type MIG-OS-OS1, MIG0603OS1, MIG-OS-OM and MIG0603OMI

Waveforms (Range): Damped sine wave:
3MHz, 10MHz and 30MHz
open circuit (up to 4 kV)
Standards: IEC61000-4-18
Accessories: CDN3000A-06-25 Power line coupling and de-coupling filter:
CWG, 100kHz Ringwave, EFT and Damped oscillatory wave (100kHz, 1MHz, 3MHz, 10MHz, 30MHz) coupling onto 3-Phase power lines up to 6 kV

MIG0603OMI

Waveforms(Range): 1 MHz, 100 kHz (up to 3kV, 200 Ohm)
1 MHz, 100 kHz (up to 100 A/m)
CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA)
0.5 J, 500 Ohm (0.5, 1, 3, 5 kV)
8/20 µs (up to 2000 A/m)
a.c. 50/60 Hz (continuous up to 100 A/m, short time 3 s up to 1000 A/m)
Coupling: MF1000-1, 100A/m
a.c.: CDN2000-06-25
up to 4 I/o lines: CND2000-06-25
Standards: IEC 61000-4-5, IEC 61000-4-8,IEC 61000-4-9, IEC 61000-4-10,IEC 61000-4-18 (1 MHz), IEC 60255-4,ANSI/IEEE C37.90.1)
Required Accessories: CDN2000-06-25, MF1000-1, MF1000-2, MF1000-3, MF1STAND

MIG-OS-OM

The MIG-OS-OM includes damped oscillatory tests 1 MHz and 100 kHz up to 3 kV in accordance with EN/IEC 61000-4-18. This standard defines a dual output for differential mode tests. Additionally magnetic field test in accordance with EN/IEC 61000-4-10 can be carried out.

Waveforms
(Range):
Damped sine wave:
100 kHz and 1 MHz
open circuit (up to 3kV)
source impedance 200 Ohm
Standards: IEC61000-4-10, IEC61000-4-18, ANSI C37-90
Accessories: CDN2000A-06-25 power line coupling and de-coupling filter:
CWG, 100kHz Ringwave, EFT and damped oscillatory wave (100kHz, 1MHz) coupling onto 3-phase power lines up to 6 kV
MF1000-1 magnetic field antenna:
Accessory to the MIG-OS-OM. Enables magnetic field testing up to 120A/m at both 100 kHz and 1 MHz.

MIG0603OSI

The MIG0603OSI includes damped oscillatory tests 1 MHz and 100 kHz up to 3 kV in accordance with EN/IEC 61000-4-18. Additional waveforms extend the application to include EN/IEC61000-4-5 and EN/IEC60255-22-1.

Waveforms
(Range):
Damped sine wave:
100 kHz and 1 MHz
open circuit (up to 3kV)
source impedance 200 Ohm
CWG 1.2/50 µs, 8/20 µs (6 kV, 3 kA)
source impedance 2 Ohm
1.2/50 µs (up to 6 kV)
source impedance 500 Ohm
Standards: EN/IEC61000-4-18, ANSI C37-90, EN/IEC61000-4-5, EN/IEC61000-4-9, EN/IEC60255-22, EN/IEC60255-5
Accessories: CDN2000A-06-25 power line coupling and de-coupling filter:
CWG, 100kHz Ringwave, EFT and damped oscillatory wave (100kHz, 1MHz) coupling onto 3-phase power lines up to 6 kV