One Box EMC Test Station

Below you find short descriptions of EMC PARTNER’s One Box EMC Test Stations:

  • Surge 4 kV,
  • Surge 4 kV and 10/700 µs 4 kV and
  • Surge 6 kV and Ring 6 kV

TRA3000

Waveforms (Range): Fast Transient, IEC 61000-4-4 Ed.2 EFT(4.4kV), 1MHz burst, SURGE IEC 61000-4-5 Ed.2 CWG 1.2/50µs (4.1kV), 8/20µs (2.05kA). DIPS IEC 61000-4-11 Ed.2. Interr. up to 16A; Variation up to 6A; CM IEC 61000-4-16 Ed.1.2, up to 35V for all continuous a.c/d.c,f.
Coupling: a.c.: single phase 16 A/260 V
d.c.: 16 A/110 V
Standards: IEC 61000-4-2, -4, -5, -8, -9, -11, -16, -29
Required Accessory: CNEFT1000 coupling clamp
EXT-TRA3000E
EXT-TRA3000 C-SHORT
EXT-TRA3000 D – 29 D
EXT-TRA3000 D – 29 I
Optional Accessory: CDN2000-06-32
CDN2000A-06-32
CDN2000A-06-63
CDN-A-3P-100-480
CDN-A-3P-100-690

TRA2004

Waveforms (Range): ESD (8/15 kV), EFT (4 kV), Surge (4 kV), DIPS (280/16 A),V-Variation (up to 280 V/6 A) 10/700 µs (4 kV), Ring 100 kHz (6 kV)
Coupling: a.c.: for single phase 16 A/260 V
d.c.: 16 A/110 V
Standards: IEC 61000-4-2, -4, -5, -8, -9, -11, -12, -16, -29, ITU K.17
Required Accessory: ESD2000
CNEFT1000
Optional Accessory: CDN2000-06-32
CDN2000A-06-32
CDN2000A-06-63
CDN-A-3P-100-480
CDN-A-3P-100-690

TRA2006

Waveform (Range): ESD (8/15 kV), EFT (4 kV), Surge (6 kV), DIPS (280 V/16 A), V-Variation (up to280 V/6 A), Ring (6 kV)
Coupling: a.c.: single phase 16 A/260 V
d.c.: 16 A/110 V
Standards: IEC/EN 61000-4-2, -4, -5, -8, -9, -11, -12, -16, -29, ANSI/IEEE C62.41, ANSI/IEEE C62.45
Options: Option 10/100
Option External CDN coupling
Option Diagnostic 1P
Required Accessory: ESD2000
CNEFT1000
Optional Accessory: CDN2000-06-32
CDN2000A-06-32
CDN2000A-06-63
CDN-A-3P-100-480
CDN-A-3P-100-690

CDN2000A-06-32

Rating: Supply Voltage (a.c. or d.c.):
L to N/PE 240 V, L to L 480 V

Supply Current:
Continuous operation (a.c. or d.c.): 3 x 32 A
Continuous operation (d.c.): 1 x 64 A

Test Voltages:
Surge voltage: maximum 6.6 kV
Ring voltage: maximum 6.6 kV
EFT voltage: maximum 4.4 kV



Control: RS232 connection from the rear side of the TRA2000 or MIG0603INx to the CDN2000A-06-32

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4
Option: 480V: for power supply L to N/PE 280 V and L to L 480 V
For use with these generators: TRA2004, TRA3000
TRA2006, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4

CDN200A-06-63

Rating: Supply Voltage (a.c. or d.c.):
L to N/PE 280 V, L to L 480 V

Supply Current:
Continuous operation (a.c. or d.c.):3 x 63 A
Continuous operation (d.c.): 3 x 30 A

Test Voltages:
Surge voltage: maximum 6.6 kV
Ring voltage: maximum 6.6 kV
EFT voltage: maximum 4.4 kV




Control: RS232 connection from the rear side of the TRA2000/TRA3000 or MIG0603INx to the CDN2000A-06-63

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4, EN-61000-4-4, EN 61000-4-5, IEC 61000-4-12, Ed.2
For use with these generators: TRA2004, TRA3000
TRA2006, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4

CDN-A-3P100-480

Rating: Supply Voltage (a.c.):
L to N/PE 280 V, L to L 480 V

Supply Current:
Continuous operation (a.c.): 3 x 100A
Continuous operation (d.c.): 3 x 63A

Test Voltages:
Surge voltage: maximum 6.6 kV
EFT voltage: maximum 4.4 kV




Control: RS232 connection from the rear side of the TRA2000/TRA3000 or MIG0603INx to the CDN-A-3P100-480

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4, EN-61000-4-4 Ed. 2.0b, EN 61000-4-5, IEC 61000-4-12 Ed.2
For use with these generators: TRA2004, TRA3000
TRA2006, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4

CDN-A-3P100-690

Rating: Supply Voltage (a.c.):
L to N/PE 400 V, L to L 690 V

Supply Current:
Continuous operation (a.c.): 3 x 100A
Continuous operation (d.c.): 3 x 63A

Test Voltages:
Surge voltage: maximum 6.6 kV
EFT voltage: maximum 4.4 kV




Control: RS232 connection from the rear side of the TRA2000/TRA3000 or MIG0603INx to the CDN-A-3P100-690

For the selection of the coupling paths see the displays on the right.

Power supply: 90 to 240 V and 50/60Hz

Standards: IEC 61000-4-5, ANSI/IEEE C62.41 and C62.45, IEC 61000-4-4, EN-61000-4-4 Ed. 2.0b, EN 61000-4-5, IEC 61000-4-12 Ed.2
For use with these generators: TRA2004, TRA3000
TRA2006, MIG0603IN,
MIG0603IN1, MIG0603IN3,
MIG0603IN4